Citation: | YUAN Li, ZHANG Xiao-hui. Surface shape measurement of large flat mirrors using a scanning pentaprism method[J].Chinese Optics, 2019, 12(4): 920-931.doi:10.3788/CO.20191204.0920 |
[1] |
赵维谦, 李文宇, 赵齐, 等.被测件随机移相干涉面形测量方法[J].光学 精密工程, 2016, 24(9):2167-2172.
http://d.old.wanfangdata.com.cn/Periodical/gxjmgc201609010
ZHAO W Q, LI W Y, ZHAO Q,
et al.. Surface measurement by randomly phase shifting interferometry of measured element[J].
Opt. Precision Eng., 2016, 24(9):2167-2172.(in Chinese)
http://d.old.wanfangdata.com.cn/Periodical/gxjmgc201609010
|
[2] |
ZHU SH, ZHANG X H. Eliminating alignment error and analyzing Ritchey angle accuracy in Ritchey Common test[J].
Optics Communications, 2013, 311:368-374.
doi:10.1016/j.optcom.2013.08.024
|
[3] |
林冬冬, 胡明勇, 李金鹏, 等.大口径平面镜局部采样瑞奇-康芒检验[J]. 与光电子学进展, 2018, 55(3):031202.
http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=jgygdzxjz201803038
LIN D D, HU M Y, LI J P,
et al.. Local sampling Ritchey-Common test for large aperture flat mirror[J].
Laser&
Optoelectronics Progress, 2018, 55(3):031202.(in Chinese)
http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=jgygdzxjz201803038
|
[4] |
王孝坤.大口径离轴凸非球面系统拼接检验技术[J].中国光学, 2016, 9(1):130-136.
//www.illord.com/CN/abstract/abstract9396.shtml
WANG X K. Measurement of large off-axis convex asphere by systemic stitching testing method[J].
Chinese Optics, 2016, 9(1):130-136.(in Chinese)
//www.illord.com/CN/abstract/abstract9396.shtml
|
[5] |
郭福东, 唐锋, 卢云君, 等.子孔径拼接干涉的快速调整及测量[J].光学 精密工程, 2017, 25(10):2682-2688.
http://d.old.wanfangdata.com.cn/Periodical/gxjmgc201710019
GUO F D, TANG F, LU Y J,
et al.. Rapid adjustment and measurement for subaperture stitching interferometry[J].
Opt. Precision Eng., 2017, 25(10):2682-2688.(in Chinese)
http://d.old.wanfangdata.com.cn/Periodical/gxjmgc201710019
|
[6] |
于瀛洁, 齐特, 武欣.大尺寸光学元件在位动态干涉拼接测量系统[J].光学 精密工程, 2017, 25(7):1764-1770.
http://d.old.wanfangdata.com.cn/Periodical/gxjmgc201707009
YU Y J, QI T, WU X. On-line dynamic interference stitching measurement system for large optical elements[J].
Opt. Precision Eng., 2017, 25(7):1764-1770.(in Chinese)
http://d.old.wanfangdata.com.cn/Periodical/gxjmgc201707009
|
[7] |
张磊, 刘东, 师途, 等.光学自由曲面面形检测技术[J].中国光学, 2017, 10(3):283-299.
//www.illord.com/CN/abstract/abstract9523.shtml
ZHANG L, LIU D, SHI T,
et al.. Optical free-form surfaces testing technologies[J].
Chinese Optics, 2017, 10(3):283-299.(in Chinese)
//www.illord.com/CN/abstract/abstract9523.shtml
|
[8] |
GECKELER R D, ARTEMIEV N A, BARBER S K,
et al.. Aperture alignment in autocollimator-based deflectometric profilometers[J].
Review of Scientific Instruments, 2016, 87(5):051906.
doi:10.1063/1.4950734
|
[9] |
SIEWERT F, ZESCHKE T, ARNOLD T,
et al.. Linear chirped slope profile for spatial calibration in slope measuring deflectometry[J].
Review of Scientific Instruments, 2016, 87(5):051907.
doi:10.1063/1.4950737
|
[10] |
QIAN J, SULLIVAN J, ERDMANN M,
et al.. Performance of the APS optical slope measuring system[J].
Nuclear Instruments and Methods in Physics Research Section A:Accelerators, Spectrometers, Detectors and Associated Equipment, 2013, 710:48-51.
|
[11] |
QIAN SH N, GECKELER R D, JUST A,
et al.. Approaching sub-50 nanoradian measurements by reducing the saw-tooth deviation of the autocollimator in the Nano-Optic-Measuring Machine[J].
Nuclear Instruments and Methods in Physics Research Section A:Accelerators, Spectrometers, Detectors and Associated Equipment, 2015, 785:206-212.
http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=310dabb1d03d9d36f183d4aaad684b52
|
[12] |
ALCOCK S G, NISTEA L, SAWHNEY K. Nano-metrology:the art of measuring X-ray mirrors with slope errors < 100 nrad[J].
Review of Scientific Instruments, 2016, 87(5):051902.
doi:10.1063/1.4949272
|
[13] |
MALLIK P C V, ZHAO CH Y, BURGE J H. Measurement of a 2-meter flat using a pentaprism scanning system[J].
Optical Engineering, 2007, 46(2):023602.
doi:10.1117/1.2700386
|
[14] |
YELLOWHAIR J, BURGE J H. Analysis of a scanning pentaprism system for measurements of large flat mirrors[J].
Applied Optics, 2007, 46(35):8466-8474.
doi:10.1364/AO.46.008466
|
[15] |
QI E H, HU H X, HU H F,
et al.. The application of pentaprism scanning technology on the manufacturing of M3MP[J].
Proceedings of SPIE, 2016, 9682:96821A.
|
[16] |
袁理, 张晓辉, 韩冰, 等.五棱镜转动时出射光角度的变化[J].中国光学, 2015, 8(6):1035-1043.
//www.illord.com/CN/abstract/abstract9358.shtml
YUAN L, ZHANG X H, HAN B,
et al.. Changes of output light's angles with pentaprism rotation[J].
Chinese Optics, 2015, 8(6):1035-1043.(in Chinese)
//www.illord.com/CN/abstract/abstract9358.shtml
|
[17] |
朱硕.大口径光学平面镜面形检测技术研究[D].北京: 中国科学院大学, 2014.
ZHU SH. Study on technology for large optic flat mirror testing[D]. Beijing: University of Chinese Academy of Sciences, 2014.(in Chinese)
|
[18] |
GECKELER R D. Optimal use of pentaprisms in highly accurate deflectometric scanning[J].
Measurement Science and Technology, 2007, 18(1):115-125.
doi:10.1088/0957-0233/18/1/014
|
[19] |
费业泰.误差理论与数据处理[M]. 6版.北京:机械工业出版社, 2010.
FEI Y T.
Error Theory and Data Processing[M]. 6th ed. Beijing:China Machine Press, 2010.(in Chinese)
|
[20] |
赖丽萍, 梁德娟, 庄其仁.聚合物光栅生物传感器光信号检测滤波电路[J].光学与光电技术, 2013, 11(1):56-59.
http://d.old.wanfangdata.com.cn/Periodical/gxygdjs201301014
LAI L P, LIANG D J, ZHUANG Q R. Filter circuits used for optical signal detection in the polymer grating biosensors[J].
Optics&
Optoelectronic Technology, 2013, 11(1):56-59.(in Chinese)
http://d.old.wanfangdata.com.cn/Periodical/gxygdjs201301014
|
[21] |
孟浩玉, 王彦, 汪诚伟, 等.基于锁相放大原理的微弱光信号检测系统设计[J].光学与光电技术, 2014, 12(6):88-91.
http://d.old.wanfangdata.com.cn/Periodical/gxygdjs201406021
MENG H Y, WANG Y, WANG CH W,
et al.. Design of the weak fluorescence signal detection system based on the principle of lock-in amplifier[J].
Optics&
Optoelectronic Technology, 2014, 12(6):88-91.(in Chinese)