摘要:结合物理光学原理和表面等离子体共振(SPR)角度传感器,提出了可以突破衍射极限的纳米间距检测方法。在理论上建立起纳米间距和位相改变量之间的函数关系,借助于SPR角度传感器的高灵敏性,提出通过检测出射光束振动方向的p分量和s分量的位相差值来实现纳米间距的实时检测。模拟结果显示:纳米间距改变量从-0.5~0.5 m变化时,位相改变量可实现-150~150的变化,检测灵敏度1 nm。该检测方法能够实现10 nm以下间距的灵敏检测,且具有结构简单,易于操作,实时检测的特点。
-
关键词:
- 表面等离子体共振(SPR)传感器/
- 角度传感器/
- 纳米间距/
- 共振角度/
- 位相差
Abstract:An optical method for the nanogap measurement beyond the optical diffraction limit was reported. The function relationship between the nanogap width and the phase difference was built. Based on the high sensitivity of a surface plasmon resonance(SPR) sensor, the nanogap width between a light transmitting mirror and a reflector could be measured by detecting the phase difference between p- and s- polarizations of the light. Numerical simulation shows that the phase difference shifts from 150 to -150 by changing the nanogap width from -0.5 to 0.5 m and the measured sensitivity of nanogap width is better than 1 nm. This nanogap measurement method can realize the measurement for the smallest gap below 10 nm and provides a simple and real-time operation beyond the physical diffraction limit. -
[1] SU D C,CHIU M H,CHEN C D. Simple two frequency laser[J].Precis. Eng.,1996,18:161-163. [2] LI Y C,CHANG Y F,SU L C,et al.. Differential-phase surface plasmon resonance biosensor[J].Anal. Chem.,2008,80:5590. [3] 冯其波.光学测量技术与应用[M].北京:清华大学出版社,2008. FENG Q B.Optical Measurement Techniques and Applications[M]. Beijing:Tsinghua University Press,2008.(in Chinese) [4] HUANG P S,NI J. Angle measurement based on the internal-reflection effect and the use of right-angle prisms[J].Appl. Opt.,1995,34:4976-4981. [5] 陈泳屹,佟存柱,秦莉,等.表面等离子体激元纳米 器技术及应用研究进展[J].中国光学,2012,5(5):453-463. CHEN Y Yi,TONG C ZH,QIN L,et al.. Progress in surface plasmon polariton nano-laser technologies and applications[J].Chinese Optics,2012,5(5):453-463.(in Chinese) [6] 刘镜,刘娟,王涌天,等.亚波长金属光栅的表面等离子体激元共振特性[J].中国光学,2011,4(4):363-368. LIU J,LIU J,WANG Y T,et al.. Resonant properties of sub-wavelength metallic gratings[J].Chinese Optics,2011,4(4):363-368.(in Chinese) [7] MOON E E,CHEN L,EVERETT P N,et al.. Nanometer gap measurement and verification via the chirped-Talbot effect[J].Vac. Sci. Technol. B,2004,22:3378. [8] KOHNO T,OZAWA N,MIYAMOTO K,et al.. High precision optical surface sensor[J].Appl. Opt.,1988,27:103-108. [9] HUANG P S,NI J. Angle measurement based on the internal-reflection effect using elongated critical-angle prisms[J].Appl. Opt.,1996,35:2239-2241. [10] ZHOU W,CAI L. Interferometer for small-angle measurement based on total internal reflection[J].Appl. Opt.,1998,37:5957-5963. [11] OZCAN M. High sensitivity displacement sensing with surface plasmon resonance[J].SPIE,2005,5927:59271T. [12] LEFLOCH S,SALVAD Y,MITOUASSIWOU R,et al.. Radio frequency controlled synthetic wavelength sweep for absolute distance measurement by optical interferometry[J].Appl. Opt.,2008,47:3027-3031. [13] SESKO D W,TOBIASON J D,FELDMAN M,et al.. A dynamically calibrated multi-wavelength absolute interfer-ometer[EB/OL].[2012-11-11].http://www.microen.com/news/odimap.pdf. [14] MAYER K M,HAO F,LEE S,et al. A single molecule immunoassay by localized surface plasmon resonance[J].Nanotechnology,2010,21:255503. [15] 齐攀,李莹,冯明创,等.用于阵列样品检测的扫描式表面等离子体共振生物传感器[J].光学 精密工程,2012,20(11):2365-2372. QI P,LI Y,FENG M CH,et al.. Scanning surface plasmon resonance biosensor for array sample detection[J].Opt. Precision Eng.,2012,20(11):2365-2372.(in Chinese) [16] 朱君,李志全.光栅耦合的可集成表面等离子体激射装置[J].光学 精密工程,2012,20(9):1899-1903. ZHU J,LI ZH Q. Integrated device of lasing SPPs with coupling grating[J].Opt. Precision Eng.,2012,20(9):1899-1903.(in Chinese) [17] WU P T,WU M C,WU C M. A nanogap measuring method beyond optical diffraction limit[J].Appl. Phys.,2007,102:123111. [18] WU P T,WU M C,WU C M. Measurement of the air gap width between double-deck metal layers based on surface plasmon resonance[J].Appl. Phys.,2010,107:083111 [19] PILIARIK M,HOMOLA J. Self-referencing SPR imaging for most demanding high-throughput screening applications[J].Sens. Actuators B,Chem.,2008,134(2):353-355. [20] WANG K,ZHENG Z,SU Y,et al.. Hybrid differential interrogation method for sensitive surface plasmon resonance measurement enabled by electro-optically tunable SPR sensors[J].Opt. Express,2009,17(6):4468-4478. [21] YUAN S W,HO H P,WU S Y,et al.. Polarization-sensitive surface plasmon enhanced ellipsometry biosensor using the photoelastic modulation technique[J].Sens. Actuators A:Phisical,2009,151:23-28. [22] KUO W K,CHANG CH H. Phase detection sensitivity enhancement of surface plasmon resonance sensor in a heterodyne interferometer system[J].Appl. Opt.,2011,50:1345-1349.
点击查看大图
计量
- 文章访问数:3141
- HTML全文浏览量:562
- PDF下载量:740
- 被引次数:0