Infrared thermometry technology with different nonuniformity correction temperatures
-
摘要: 为使制冷型中波红外热像仪在不同环境温度下经过非均匀性校正后保持较高的测温精度,研究了考虑非均匀性校正温度效应的中波红外热像仪标定模型。利用不同温度的面源黑体对热像仪进行非均匀性校正,然后对黑体目标进行测温实验,获得了不同校正温度下热像灰度与黑体辐射亮度之间的变化关系,建立了目标的测温数学计算模型,最后对测温结果进行误差分析。结果表明:在不同校正温度下,热像灰度相对非均匀校正辐亮度的漂移可做线性化处理,且与目标温度变化无关。在非均匀性较低的测温范围内热像仪的测温误差小于0.22 ℃,极大减小了制冷型中波红外热像仪在不同校正温度下非均匀性校正后的测温误差。Abstract: In order to keep high accuracy of temperature measurement of the cooled medium-wave infrared thermal imager after nonuniformity correction under different ambient temperatures, the calibration model of the medium-wave infrared thermal imager is analyzed with the consideration of the effect of the nonuniformity correction temperature. The nonuniformity of thermal imager is corrected using surface blackbody under different temperatures. The relationship between the gray and blackbody radiance is obtained by thermometry experiment of blackbody target. The mathematical calculation model of target temperature is established and the error of thermometry result is analyzed. The results show that the drift of gray of thermal image as nonuniformity correction radiance under different correction temperatures can be treated linearly, and is independent on the target temperature. When the nonuniformity is low, the temperature measurement error of the thermal imager is less than 0.22 ℃, which greatly reduces the temperature measurement error of the cooled medium-wave infrared thermal imager after nonuniformity correction under different correction temperatures.
-
[1] 陈世伟, 杨小冈, 张胜修, 等. 基于变积分时间的红外焦平面非均匀性校正算法研究[J]. 光子学报, 2013, 42(4):475-479. CHEN SH W, YANG X G, ZHANG SH X, et al.. Research on nonuniformity correction algorithm of IRFPA based on adjusting integral time[J]. Acta Photonica Sinica, 2013, 42(4):475-479.(in Chinese) [2] 曹扬, 金伟其, 刘崇亮, 等. 红外焦平面阵列的自适应非均匀性校正及硬件实现[J]. 光学 精密工程, 2011, 19(12):2985-2991. CAO Y, JIN W Q, LIU CH L, et al.. Adaptive nonuniformity correction and hardware implementation of IRFPA[J]. Opt. Precision Eng., 2011, 19(12):2985-2991.(in Chinese) [3] 白俊奇, 陈钱, 钱惟贤, 等. 基于环境温度的红外焦平面阵列非均匀性校正[J]. 红外与毫米波学报, 2010, 29(1):49-52. BAI J Q, CHEN Q, QIAN W X, et al.. Nonuniformity correction for infrared focal plane arrays based on environmental temperature[J]. J. Infrared Millim. Waves, 2010, 29(1):49-52.(in Chinese) [4] DONG L Q, LIU X H, ZHAO Y J, et al.. Scene-based nonuniformity correction algorithm for MEMS-based un-cooled IR image system[J]. SPIE, 2009, 74190Y:1-12. [5] 杨词银, 张建萍, 曹立华. 基于大气透过率比例校正的目标辐射测量[J]. 光学 精密工程, 2012, 20(7):1626-1635. YANG C Y, ZHANG J P, CAO L H. Infrared radiation measurement based on proportional corrected atmospheric transmittance[J]. Opt. Precision Eng., 2012, 20(7):1626-1635.(in Chinese) [6] 孙志远, 王 晶, 乔彦峰. 环境对中波红外探测器测温精度的影响[J]. 中国光学与应用光学, 2010, 3(6):659-664. SUN ZH Y, WANG J, QIAO Y F. Influence of environment on temperature measurement precision based on middle-wave IRFPA[J]. Chinese J. Opt. and Appl. Opt., 2010, 3(6):659-664.(in Chinese) [7] 孙志远, 朱 玮, 乔彦峰. 红外测温过程中灰度值漂移的修正[J]. 中国光学与应用光学, 2010, 3(4):391-396. SUN ZH Y, ZHU W, QIAO Y F. Amendment of gray drift of in infrared temperature measurement[J]. Chinese J. Opt. Appl. Opt., 2010, 3(4):391-396.(in Chinese) [8] GEORGE M W, ARCHIE B. Dual-band MWIR/LWIR radiometer for absolute temperature measurements[J]. SPIE, 2006, 62050M:4-13. [9] 陆子凤. 红外热像仪的辐射定标和测温误差分析[D].长春:中国科学院长春光学精密机械与物理研究所, 2010. LU Z F. Calibration and the measurement error analysis of infrared imaging system for temperature measurement[D]. Changchun:Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, 2010.(in Chinese) [10] 李宁, 杨词银, 曹立华, 等. 3~5 μm红外焦平面阵列的辐射定标[J]. 光学 精密工程, 2011, 19(10): 2319-2325. LI N, YANG C Y, CAO L H, et al.. Radiance calibration for 3~5 μm infrared focal plane array[J]. Opt. Precision Eng., 2011, 19(10):2319-2325.(in Chinese)
点击查看大图
计量
- 文章访问数: 1443
- HTML全文浏览量: 217
- PDF下载量: 838
- 被引次数: 0