Star position correction of dynamic star simulator based on TFT-LCD
-
摘要:介绍了基于TFT-LCD的动态星模拟器的工作原理及星点位置误差的计算方法。利用经纬仪对动态星模拟器显示的网格星点进行测量,计算了各星点的位置误差及修正系数。对网格上星点的修正系数进行分区处理,并利用Matlab软件对各分区的修正系数进行曲线拟合,得到修正系数关于星点位置(方位或俯仰)坐标的方程。结果表明,修正后星点的位置误差均小于35,满足动态星模拟器的设计要求。Abstract:This paper describes the working principle of the dynamic star simulator based on a TFT-LCD and the calculation of the revised star angular distance error. A theodolite is used to measure the star point on the grid shown by the dynamic star simulator, then the position error correction factor of each star point is calculated based on the measured data. The correction coefficient of the star point on the grid is partitioned, and Matlab software is used for the curve fitting of each partition's revised correction coefficients to get the(azimuth or elevation) coordinate equations of the star position. The experimental result shows that the revised star angular distance error is less than 35, which meets the design requirements of the dynamic star simulator.
-
Key words:
- dynamic star simulator/
- theodolite/
- curve fitting
-
[1] 刘亚平,李娟,张宏. 星模拟器的设计与标定[J]. 红外与 工程 ,2006,35(增1):331-334. LIU Y P,LI J,ZHANG H. Design and calibration of star simulator[J].Infrared and Laser Eng.,2006,35(s1):331-334.(in Chinese) [2] 赵晨光,谭久彬,刘俭,等. 用于天文导航设备检测的星模拟装置[J]. 光学 精密工程 ,2010,18(6):1326-1332. ZHAO CH G,TAN J B,LIU J,et al.. Star simulator for testing celestial navigation equipment[J].Opt. Precision Eng.,2010,18(6):1326-1332.(in Chinese) [3] 张文明,林玲,郝永杰,等. 小型星模拟器中星图动态显示系统的设计[J]. 光电工程 ,2000,27(5):11-14. ZHANG W M,LIN L,HAO Y J,et al.. Design of a dynamic display system for star map in small-sized star simuator[J].Opto.Elect ronic Eng.,2000,27(5):11-14.(in Chinese) [4] 巩岩,胡宜宁,赵阳. 基于数字光处理技术的小型星模拟器设计[J]. 光学 精密工程 ,2007,15(11):1698-1704. GONG Y,HU Y N,ZHAO Y,et al.. Design of a mini star simulator based on digital optical processing[J].Opt. Precision Eng.,2007,15(11):1698-1704.(in Chinese) [5] 蒋汉元,李雪雷,陈涛,等. 光电经纬仪图像测量中的自动调焦系统研究[J]. 计算机测量与控制, 2010,18(1):183-185. JIANG H Y,LI X L,CH T,et al.. Research on automatic focusing system for theodolite's image measurement[J].Computer Measurement&Control,2010,18(1):183-185.(in Chinese) [6] 李春艳,李怀锋,孙才红. 高精度星敏感器天文标定方法及观测分析[J]. 光学精密工程 ,2006,14(4):558-563. LI CH Y,LI H F,SUN C H. A stronomical calibration method and observation analysis for high-accuracy star sensor[J].Opt. Precision Eng.,2006,14(4):558-563.(in Chinese) [7] 段晓东. 全天球实时星光模拟器的设计与标定[J]. 控制工程 ,1997(2):23-33. DUAN X D. Design of real-tiem star simulator in whole celestial sphere[J].Controlling Eng.,1997(2):23-33.(in Chinese) [8] 刑飞 ,武延鹏 ,董瑛,等. 微型星敏感器实验室测试系统研究[J]. 光学技术 ,2004,30(6):703-709. XING F,WU Y P,DONG Y,et al.. Research of laboratory test system for micro-star tracker[J].Opt Tech.,2004,30(6):703-709(in Chinese) [9] 唐建国,袁家虎,吴钦章. 液晶光阀星图模拟设计与实现[J]. 光电工程 ,1999,26(增):75-78. TANG J G,YUAN J H,WU Q ZH. Design and implementation of star pattern simulation with liquid crystalight valve[J].Opto-Electronic Eng.,1999,26(s):75-78.(in Chinese)
点击查看大图
计量
- 文章访问数:4266
- HTML全文浏览量:327
- PDF下载量:1507
- 被引次数:0