  • The Liou-Brennan eye model is constructed using the optical design software ZEMAX. The Depth of Focus(DOF), extended Intraocular Lenses(IOL) that includes aspherical IOL, refractive multifocal IOL and diffractive multifocus IOL are included in the design. The optical performance of the pseudophakic eye for the designed IOLs is analyzed for both the spot diagram and visual acuity. For the pseudophakic eye with a 3 mm pupil, when the spherical aberration is fully corrected by the aspherical IOL, the best visual acuity reaches 1.2 with a DOF of only 1.4 m-1. When the spherical aberration is 0.4, the best visual acuity is 0.9 with a DOF as high as 2.2 m-1. With the implantation of refractive or diffractive multifocus IOLs, the pseudophakic eye has fairly good distant and near vision, while the intermediate vision is lower than 0.5. Diffractive multifocal IOL allows 81% input energy to image and the energy distribution is not affected by the pupil size. The energy distribution of the refractive multifocal IOL is dependent on the pupil diameter. The aspherical IOL, refractive multifocal IOL and diffractive multifocal IOL can extend DOF after surgery. However, they all have advantages and disadvantages, which should be taken into consideration under clinical conditions.

  • loading
  • [1] DAVISON J A,SIMPSON M J. History and development of the apodized diffractive intraocular lens[J]. J.Cataract Refract. Surg.,2006,32(5):849-858. [2] 饶丰. 基于个性化眼模型的人工晶体设计及其特性研究.天津:南开大学光学研究所,2010. RAO F. Study on the design and the performance of intraocular lenses based on individual eye models. Tianjin:Institute of Modern Optics,Nankai University,2010.(in Chinese) [3] NEGISHI K,OHNUMA K,IKEDA T, et al.. Visual simulation of retinal images through a decentered monofocal and a refractive multifocal Intraocular Lens[J]. Jpn. J. Ophthalmol.,2005,49(4):281-286. [4] PIEH S,MARVAN P,LACKNER B, et al.. Quantitative performance of bifocal and multifocal intraocular lenses in a model eye:point spread function in multifocal intraocular lenses[J]. Arch. Ophthalmol.,2002,120(1):23-28. [5] 王幼生,廖瑞瑞,刘泉,等.现代眼视光学[M]. 广州:广东科技出版社,2006. WANG Y SH,LIAO R R,LIN Q, et al.. Advanced Vision Optics[M]. Guangzhou:Guangdong Science Press,2006.(in Chinese) [6] HARMAN F E,MALING S,KAMPOUGERIS G, et al.. Comparing the 1CU accommodative, multifocal, and monofocal intraocular lenses:a randomized trial[J]. Ophthalmology,2008,115(6):993-1001. [7] EPPIG T,SCHOLZ K,LOFFLER A, et al.. Effect of decentration and tilt on the image quality of aspheric intraocular lens designs in a model eye[J]. J.Cataract Refract. Surg.,2009,35(6):1091-1100. [8] RAO F,WANG Z Q,WANG Y, et al.. Achromatic customized intraocular lens based on an individual pseudophakic eye model[J]. Optik,2010,121(4):366-372. [9] ZLOTNIK A,YAISH S B,YEHEZKEL O. Extended depth of focus contact lenses for presbyopia[J]. Opt. Lett.,2009,34(14):2219-2221. [10] LIOU H L,BRENNAN N A. Anatomically accurate, finite model eye for optical modeling[J]. J. Opt. Soc. Am. A,1997,14(8):1684-1695. [11] LIU T,WANG Z Q,WANG Y, et al.. The study of the effects of higher-order aberrations on human contrast sensitivity with white-light retinal aerial image modulation[J]. Optik,2010,121(12):1116-1122. [12] WANG W,WANG Z,WANG Y. Measurements of AIM for visible wavelength based on individual eye model[J]. Chin. Phys. Lett.,2006,23(12):3263-3266. [13] 徐广第.眼科屈光学 [M].第4版.北京:军事医学科学出版社,2005:129. XU G D. Ophthalmology Refraction[M]. 4th ed. Beijing:Military Medical Science Press,2005.(in Chinese) [14] PACKERr M,HOFFMAN R S,HOWARD F. Refractive Lens Surgery[M]. Berlin:Springer-Verlag,2005. [15] 谭少健,梁皓,李霞,等. 多焦点人工晶状体眼早期视觉质量的研究[J]. 眼科,2005,14(1):17-22. TAN SH J,LIANG H,LI X, et al.. Early postoperative visual function after multifocal intraocular lens implantation[J]. Ophthalmol. Chin.,2005,14(1):17-22.(in Chinese)
  • 加载中

Catalog

    通讯作者:陈斌, bchen63@163.com
    • 1.

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views(2886) PDF downloads(1063) Cited by()
    Proportional views

    /

      Return
      Return
        Baidu
        map