  • Publish Date:10 Feb 2013
  • An irreversible adherence method is proposed to bond the microfluidic channel of a waveguide biosensor to orercome the liquid leaks from the traditional reversible adherence. Several methods on irreversible adherence between Polydimethylsiloxane(PDMS) and Silicon-on-Insulator(SOI) waveguide in the micro-fluidic channel of bio-sensor are illustrated, that is, irradiation with ultraviolet light, activation surface by oxygen plasma, oxidizing surfaces into SiO2 and ultraviolet glue. Firstly, the PDMS and SOI waveguide surfaces are treated with the four methods. Secondly, the bonding capacities are tested and the adherence effect is analysed in quantity. Finally, the activation surface by oxygen plasma is selected as the most effective method for irreversible adherence and other factors probably affecting the adherent effect in the experiment are also discussed.

  • loading
  • [1] ANDERSON R R,HU W,NOH J W, et al.. Transient deflection response in microcantilever array integrated with polydimethylsiloxane(PDMS) microfluidics[J]. Lab. Chip, 2011,11:2088-2096. [2] PARK K,MILLET L J,KIM N, et al.. Measurement of adherent cell mass and growth[J]. Pro. Nati. Acad. Sci. USA,2010,107:20691-20696. [3] ANG P K,LOH K P,LI A, et al.. Flow sensing of single cell by graphene transistor in a microfluidic channel[J]. Nano Letters,2011,11:5240-5246. [4] HWANG S Y,KWON K W,JANG K J, et al.. Adhesion assays of endothelial cells on nanopatterned surfaces within a microfluidic channel[J]. Anal. Chem.,2010,82:3016-3022. [5] KIM S K,CHO H,PARK H K, et al.. Fabrication of nanochannels by anisotropic wet etching on silicon-on-insulator wafers and their application to DNA stretch[J]. J. Nanoscience and Nanotechnology2010,10:637-642. [6] SHI J,YAZDI S,LIN S C S, et al.. Three-dimensional continuous particle focusing in a microfluidic channel via Standing Surface Acoustic Waves(SSAW)[J]. Lab Chip,2011,11:2319-2324. [7] SCHONBRUN E,ABATE A R,STEINVURZEL P E, et al.. High-throughput fluorescence detection using an integrated zone-plate array[J]. Lab Chip,2010,10:852-856. [8] DITTRICH P S,MANZ A. Lab-on-a-chip:microfluidics in drug discovery[J]. Nat. Rev. Drug Discov.,2006,5:210-218. [9] DENSMORE A,XU D X,WALDRON P, et al. Silicon microphotonic waveguides for biological sensing[J]. International Symposium on Biophotonics, Nanophotonics and Metamaterials,2006. Oct.16-18,2006,Hangzhou,China,2006. [10] MCDONALD J C,DUFFY D C,ANDERSON J R, et al.. Fabrication of microfluidic systems in poly(dimethylsiloxane)[J]. Electrophoresis,2000,21:27-40. [11] 程莉莉,余冬冬,邓晓清, 等.玻璃-PDMS微流控芯片制备工艺[J]. 武汉工程大学学报,2009:31(1):58-61. CHENG L L,YU D D,DENG X Q, et al.. Fabrication of glass/PDMS micro-fluidic chips[J]. J. Wuhan. Inst. Tech,2009,31(1):58-61.(in Chinese) [12] XU X,SUBBARAMAN H,PHAM D, et al.. Transfer and characterization of silicon nanomembrane-based photonic devices on flexible polyimide substrate[J]. SPIE,2011,7944:79440F. [13] ANDERSON J R,CHIU D T,JACKMAN R J, et al.. Fabrication of topologically complex three-dimensional microfluidic systems in pdms by rapid prototyping[J]. Anal. Chem.,2000,72:3158-3164. [14] DUFFY D C,MCDONALD J C,SCHUELLER O J A, et al.. Rapid prototyping of microfluidic systems in poly(dimethylsiloxane)[J]. Anal. Chem.,1998,70:4974-4984. [15] KURKURI M D,AL-EJEH F,SHI J Y, et al.. Plasma functionalized PDMS microfluidic chips:towards point-of-care capture of circulating tumor cells[J]. J. Mater. Chem.,2011,21:8841-8848. [16] TSAI L F,DAHLQUIST W C,KIM S H, et al..Bonding of Polydimethylsiloxane(PDMS) microfluidics to silicon-ased sensors[J]. Sensors and Actuators B:Chemical,2011,10(4):043009. [17] KIN D,SEDLAK M, et al.. Poly(dimethylsiloxane)(PDMS) and silicon hybrid biochip for bacterial culture[J]. Biomedical Microdevices,2003,5(4):281-290. [18] 薛向尧,张平,黎海文, 等.PDMS氧等离子体长效活性表面处理及与Si的键合[J]. 功能材料与器件学报,2008,14(5):877-882. XUE X Y,ZHANG P,LI H W, et al.. Long term active surface modification of poly(dimethylsiloxane)by o 2plasma and the PDMS—silicon hybrid bonding[J]. J. Functional Materials and Devices,2008,14(5):877-882.(in Chinese) [19] TANG K C,LIAO E,ONG W L, et al.. Evaluation of bonding between oxygen plasma treated polydimethyl siloxane and passivated silicon[J]. J. Phy.:Conf. Ser.,2006,34:155-161. [20] 孟斐,陈恒武,方群, 等.聚二甲基硅氧烷微流控芯片的紫外光照射表面处理研究[J]. 高等学校化学学报,2002,23(7):1264-1268. MENG F,CHEN H W,FANG Q, et al.. Surface modif ication of poly(dimethylsiloxane)-fabricated microfluidic chip by UV radiation[J]. Chemical J. Chinese Universities,2002,23(7):1264-1268.(in Chinese)
  • 加载中

Catalog

    通讯作者:陈斌, bchen63@163.com
    • 1.

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views(2869) PDF downloads(811) Cited by()
    Proportional views

    /

      Return
      Return
        Baidu
        map